Multi-wire systems: 3, 4 and 5 wires
Most older New York apartment intercoms use several common wires, shared by every apartment, and one selective wire per apartment that carries its call.
| System | Common | Selective | Example station |
|---|---|---|---|
| 3-wire | 2 | 1 | Lee-Dan IR-203 |
| 4-wire | 3 | 1 | Lee-Dan IR-204 |
| 5-wire | 4 | 1 | Lee-Dan IR-205 |
The riser cable carries the common wires plus one selective wire for every apartment on that line.
Swipe sideways to see the whole diagram.
Two-wire systems
Newer systems put power, voice, video and calls on two wires. Each apartment unit has an address, so the system reaches it digitally instead of on its own wire. Comelit's Simplebus and the DT-607 2-wire panels are examples.
This is why older buildings can often get video without rewiring: they already have more than two wires to every apartment.
Network cable
IP intercoms use network cable, usually to the door panel at least, and often to each apartment monitor. Where an old riser can't carry network signals, a new cable is run alongside it.
What wire count tells you about faults
- One apartment affected: its selective wire or its station.
- A whole line affected: a common wire in that riser.
- Two apartments ring together: their selective wires are touching.
Testing old wire
Before reusing wire we test every conductor for breaks, shorts and leakage between wires. Old cable can look fine and still be corroded inside a wall. See replacement and upgrades.
Common questions
How do I count the wires in my system?
Take the apartment station off the wall and count the wires on its terminals, or read the model number.
Can I mix stations with different wire counts?
No. Every station on a line must match the system's wire count.